Nortel Networks NN43001-318 Network Card User Manual


 
Installing ISDN BRI hardware for trunk applications 39
2. Install the MISP.
3. Install clock referencing on the SILC.
4. Install the SILC and/or UILC.
5. Connect the system to the MDF.
6. Cross-connect the MDF (in Terminal Equipment mode).
Note: The system, in TIE trunk or CO connectivity, requires a
different wiring configuration than for a line application; the transmit
and receive pairs should be reversed, as illustrated in Figure 12
"Connect the network termination to the U interface and to the S/T
interface (in TE mode)" (page 43).
Selecting the card slots
Follow the same procedures as described earlier for line applications (refer
to Procedure 1 "Selecting the card slots" (page 16)).
Removing the module cover for card installation
Follow the same procedures as described earlier for line applications (refer
to Procedure 2 "Remove the module cover for card installation" (page 20)).
Installing the MISP
Follow the same procedures as described for line applications (refer to
Procedure 3 "Installing the MISP" (page 21)).
Installing the clock reference on the SILC
The DSL#0 and DSL#1 on an SILC card can be configured as the reference
clock source, with DSL#0 being assigned for the primary clock reference
and DSL#1 being assigned for the secondary clock reference.
The loop number and location of the primary and secondary clock source is
configured in the Digital Data Block LD 73. Refer to the ISDN Basic Rate
Interface Feature Fundamentals (NN43001-580).
Procedure 11
Providing clock referencing on the SILC
Step Action
Complete the following procedure to provide clock referencing on the SILC.
To install the NTRB53 Clock Controller for CS 1000 Release 4.0
refer to ISDN Primary Rate Interface Installation and Commissioning
(NN43001-301).
1
Maintain the same polarity on each transmit and receive. Rewire
the selected Tx and Rx pairs (applicable to DSL0 and DSL1) to
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2003-2007, Nortel Networks
.