Nortel Networks 5399 Network Card User Manual


 
Nortel Networks 5399 and 8000 Access Switch SNMP MIB Reference
5-4 300861-C Rev. 00
Thresholds
The threshold values are user selectable and range from 0 to 65535. When the
MIB counter meets or exceeds the threshold value, the corresponding trap is sent
to the trap hosts. Setting the threshold value to 0 disables the corresponding error
trap while setting the threshold to a higher number reduces the network traffic.
Table 5-3. Total Error Counter MIBs
MIB Object Name Description
anxt1TotalIndex The index value of the DS1 interface for the selected interval.
anxt1TotalOofs The number of OOF events for the selected interval. (An event
begins when any two out of four consecutive frame
synchronizing bits are received from the network interface are
incorrect.) An OOF state ends when reframe occurs.
anxt1TotalBpvs The number of bipolar violation errors for the selected interval.
(Bipolar violation is the occurrence of two consecutive pulses
with the same polarity.)
anxt1TotalCrcs The number of CRC errors for the selected interval. (DS1
signal from incoming call does not agree with DS1 signal from
the network.)
anxt1TotalCs The number of DS1 frames which are replicated or deleted in
the selected interval.
anxt1TotalRnacs The number of network alarms occurring in the selected
interval. (This is expressed in seconds with at least one alarm
occurring per second.)
anxt1TotalEsfError The extended superframe errors count in the selected interval.
anxt1TotalLofc The loss of framing errors count in the selected interval.