Nortel Networks V100 Server User Manual


 
NN10364-301 MCS 5100 3.5 Standard 6.0 December 2006
114
Copyright © 2006 Nortel Networks
14 Use the values from the following table to enter into the Overload
Controls tab parameters.
Service
Parameter:
Label
Private_Service_Address not applicable default
Value: <leave blank> default
Service
Parameter:
Label
CallPark.TokenRange Range is 1-80
characters
default
Value: This is the value to enter
if you have the ability to
park a call. For more
information, see the
MCS SIP Application
Module Basics
(NN10259-111)
document.
default
Table 14 Server Properties tab (Sheet 2 of 2)
Parameter Recommended value Notes Example
Table 15 Overload Controls tab
Parameter
Recommended
value Notes Example
Mem Polling Interval (sec) 10 default
Minor Alarm Threshold (%) 80 default
Major Alarm Threshold (%) 85 default
Critical Alarm Threshold (%) 90 default
Call queue high threshold 70 70
Call queue low threshold 40 40
Other queue high threshold 40 default
Other queue low threshold 5 default
Database queue high threshold 40 40