. 8 discrete inputs for dry contact switches
. 230 V ac provided on input high side
. Returns commoned internally
. Pulse counting option
. 230 V ac Bussed Field Power required
Module Specications (See also System Specification)
Inputs
Number of channels ...........................................................................8
OFF current ..........................................................................< 0.28 mA
ON current............................................................................> 0.71 mA
Wetting current .........................................1 mA (nom.) @ 230 V ac
Congurable Parameters
Selectable input filter ...........................fast, slow or user defined
(User defined permits 0 to 512 ms values in 2ms steps)
Latch inputs................................................................enable /disable
Latch polarity......................................latch on high / latch on low
Pulse counting ..........................................................enable /disable
Response Time
I/O response time
Field event to new data available on Railbus....33 ms (max.)
Power Supplies
Railbus (12V) current......................................................40 mA (typ.)
...........................................................................................60 mA (max.)
Bussed Field Power ..................................................207 to 265 V ac
Frequency ............................................................................50 / 60 Hz
Mechanical
Module Key Code..............................................................................E2
Module width ............................................................................42 mm
Weight............................................................................................170 g
NT-8114-DI-AC
Image Description
8-channel Discrete Input
230 V ac, non-isolated, module powered
Field Terminals
Field Wiring Recommended
Field Terminal
Compatible
Field Terminal
General Purpose NT-8604-FT-FU
Fused
NT-8602-FT-ST
Standard †
Class 1, Div 2
or Zone 2 hazard-
ous area
NT-8611-FT-FU
Non-arcing,
Fused
NT-8610-FT-NA
Non-arcing †
† Alternative fusing in the field wiring is recommended if it is
not provided in the field terminal.