2.4.8 A/D Mode Control Register
(WRITE) Base+B : A/D Mode Control Register Format
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
X SI2 SI1 SI0 X D2 D1 D0
X=don‘t care
Mode Select Trigger Type Transfer Type
D2 D1 D0 Software Trig Pacer Trig Software Interrupt
0 0 0 Select X Select X
0 0 1 Select X Select X
0 1 0 X Select X X
1 1 0 X Select Select Select
X=disable
SI2 SI1 SI0 IRQ Level
0 0 0 IRQ2
0 0 1 Not used
0 1 0 IRQ2
0 1 1 IRQ3
1 0 0 IRQ4
1 0 1 IRQ5
1 1 0 IRQ6
1 1 1 IRQ7
The A/D conversion operation can be divided into 2 stages, trigger stage and transfer
stage. The trigger stage will generate a trigger signal to the A/D converter and the transfer
stage will transfer the results to the CPU.
The trigger method may be an internal trigger or an external trigger. The internal
trigger can be a software trigger or a pacer trigger. The software trigger is very simple
but can not control the sampling rate very precisely. In software trigger mode, the
program issues a software trigger command (sec. 2.4.9) any time needed. Then the program
will poll the A/D status bit until the ready bit is 0 (sec. 2.4.2).