Omron CJ2 Network Card User Manual


 
35
MECHATROLINK-II-compatible Position Control Units
Unit
classification
Product name Specifications
No. of
unit
numbers
allocated
Current
consumption
(A)
Model Standards
5 V 24 V
CJ CPU
Bus Units
MECHATROLINK-II-
compatible
Motion Control Units
Control commands executed by MECHATROLINK-II
synchronous communications.
16 axes max.
Direct operation by ladder programming.
Control mode: Position control, speed control,
or torque control
1 0.36 CJ1W-NCF71 UC1, CE
MECHATROLINK-II-compatible Motion Control Units
Unit
classification
Product name Specifications
No. of
unit
numbers
allocated
Current
consumption
(A)
Model Standards
5 V 24 V
CJ CPU
Bus Units
MECHATROLINK-II-
compatible
Motion Control Units
Position, speed, and torque commands by
MECHATROLINK-II
32 axes max. (Physical axes: 30, Virtual axes: 2)
Motion control language
1 0.6 CJ1W-MCH71 UC1, CE
Note: The CJ1W-MCH71 requires the space of three Units (but just one unit number). A maximum of 10 Units can be mounted
on a single CJ-series Rack, up to three CJ1W-MCH71 Motion Control Units plus one other Unit can be mounted per Rack.
Serial Communications Units
Unit
classification
Product name
Specifications
No. of
unit
numbers
allocated
Current
consumption
(A)
Model Standards
Communications
Interface
Communications functions 5 V 24 V
CJ CPU
Bus Units
Serial
Communications
Units
1 RS-232C port and
1 RS-422A/485 port
The following functions can be
selected for each port:
Protocol macro
Host Link
NT Links (1:N mode)
Serial Gateway (See note 1.)
No-protocol (See note 2.)
Modbus-RTU Slave (See note 3.)
1
0.38
(See
note 4.)
CJ1W-SCU41-V1
UC1, N, L,
CE
2 RS-232C ports
0.28
(See
note 4.)
CJ1W-SCU21-V1
2 RS-422A/485 ports 0.38 CJ1W-SCU31-V1
Note 1. The Serial Gateway function is enabled only for Serial Communications Units of unit version 1.2 and later.
2. The no-protocol function is enabled only for Serial Communications Units of unit version 1.2 and later (and a CPU Unit of unit version 3.0 or later is also required).
3. The Modbus-STU Slave function is enabled only for Serial Communications Units of unit version 1.3 and later.
4. When an NT-AL001 RS-232C/RS-422A Conversion Unit is used, this value increases by 0.15 A/Unit. When a CJ1W-CIF11 RS-422A Conversion Unit is used, it increases by 0.04 A/Unit.
EtherNet/IP Unit
Unit
classification
Product
name
Specifications
No. of
unit
numbers
allocated
Current
consumption (A)
Model Standards
Communications
cable
Communications
functions
Max.Units
mountable
per CPU
Unit
5 V 24 V
CJ CPU
Bus Units
EtherNet/IP
Unit
STP (shielded
twisted-pair) cable
of category 5, 5e, or
higher.
Tag data link
message service
8
(See note)
1 0.41 CJ1W-EIP21
UC1, N, L,
CE
Note: Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU -EIP CPU Unit.
Ordering Information