50 PowerScan
®
Scanner
Setting Global
Suffix(es)
One or two suffix characters may be added to the standard label format
when desired. For the addition of more than two suffix characters, con-
tact your distributor or technical support representative for Full Label
Edit (FLE) options.
Identify your specific system requirements before adding or modifying
these settings, then follow these steps:
1. Look at the ASCII chart shown on the inside back cover of this
manual, and identify the ASCII character(s) and the corre-
sponding Hex Code(s) for the ASCII characters you will use as
suffixes.
For example, if you are going to send two suffix characters as ‘LF’ (Line
Feed) and ‘CR’ (Carriage Return). The ASCII chart shows that ‘LF’
equals 0A hex and ‘CR’ equals 0D hex.
2. Scan the SET bar code on page 51.
3. Scan the Set Suffix bar code.
4. Turn to Appendix C: Keypad on page 147, and scan the four dig-
its corresponding to the Hex Values determined in step one
above. (For the example, scan 0, A, 0, D). Return to this page
and go to step five.
Setting Global Prefix(es)
SET -------------------------------------------
Set Prefix ---------
END ------------------------------------------
IMPORTANT NOTE
If you are using the Universal Wedge interface,
do not modify the suffix setting. Refer to the
Universal Wedge Programming Guide to mod-
ify the suffix settings.