34 1892 1335 - Orion Radio Modem Operating Instructions - v1.3 / Aug 2006
04 IDS IDD 60 aaaa bbbb cccc dddd
CH
Analogue input levels (reply to 40 command)
aaaa = ADC level of analogue input 0, 1 - 1023
bbbb = ADC level of analogue input 1, 1 - 1023
cccc = ADC level of analogue input 2, 1 - 1023
dddd = ADC level of analogue input 3, 1 - 1023
04 IDS IDD 61 nn CH
Digital input levels (reply to 41 command or after an
alarm)
Logic 0 in byte nn indicates output = Low
Logic 1 in byte nn indicates output = High
04 IDS IDD 62 nn aaaa CH
Analogue input level for port nn (reply to 42 command or
after an alarm)
aaaa = ADC level of analogue input nn 1 - 1023
04 IDS IDD 65 nn cccc CH
Pulse counter value (reply to 45 command)
cccc = 1 - 1023
04 IDS IDD 66 cccc pp CHCH
Used channel and power setting (reply to 46 command)
cccc = channel 1 - 400
pp = 0, low power and pp = 1, high power
04 IDS IDD 67 nn aaaa CH
Analogue output level for port nn (reply to 47 command)
aaaa = 1 - 255 with 16 bit reserved
04 IDS IDD 68 nn CH
Digital output status (reply to command 47)
Logic 0 in byte nn indicates output = Low
Logic 1 in byte nn indicates output = High
04 IDS IDD 69 bbbb CH
Power supply battery trip level (reply to command 49)
bbbb = alarm trip level 1 - 1023
04 IDS IDD 70 bbbb CH
Pulse counter alarm trip level (reply to commands 30 and
33)
bbbb = 1 - 1023
04 IDS IDD 73 bbbb CH
Poll counter alarm trip level (reply to command 30)
bbbb = 1 - 1023
04 IDS IDD 74 aaaa CH
RSSI level for last received message (reply to command
48)
aaaa = 1 - 1023
04 IDS IDD 91 nn bb CH
Digital input alarm for port nn
00 in byte bb indicates output = Low
FF in byte bb indicates output = High
04 IDS IDD 92 aaaa CH
Analogue input alarm for port nn
aaaa = 1 - 1023
04 IDS IDD 93 aaaa CH
Pulse count alarm when pulse count > alarm trip level
aaaa = 1 - 1023