Panasonic BT-LH80WE Computer Monitor User Manual


 
32
REMOTE Specifications (continued)
RS-232C terminal
Assignment of item priority levels
When both “MARKER1” and “MARKER2” are ON at the same time, “MARKER1” has priority. However, when
the display aspect is 4:3, the “MARKER1” aspect is 16:9, and the “MARKER2” aspect is 4:3, “MARKER2” is
displayed. In this case, the “MARKER2” background is controlled.
When “MARKER BACK HALF” and “MARKER BACK BLACK” are simultaneously activated, priority goes to
“MARKER BACK BLACK”.
When two or more of the following items - “INPUT SEL. VIDEO”, “INPUT SEL. VF”, “INPUT SEL. SDI” and
“INPUT SEL. YP
BPR” - are simultaneously activated, priority goes to the last item activated.
Refer to the following diagram and lower right table for the RS-232C terminal pin arrangement and connections.
Please contact the vendor for information about detailed systems which used the RS-232C.
RS-232C Terminal (9P)
PC Side (Straight) BT-LH80W Side
Pin number Signal Pin number Signal
1 N.C. 1 N.C.
2 RXD 2 TXD
3 TXD 3 RXD
4 DTR 4 DSR
5 GND 5 GND
6 DSR 6 DTR
7 RTS 7 CTS
8 CTS 8 RTS
9 N.C. 9 N.C.
RS-232C REMOTE operation method
Connectors and signal names
Connector: D-SUB 9-pin (female)
Signal name
Pin
number
Signal
name
Explanation
1 N.C. Not connected
2 TXD Transmission data
3 RXD Reception data
4 DSR Connected inside.
5 GND Ground
6 DTR Connected inside.
7 CTS Connected inside.
8 RTS Connected inside.
9 N.C. Not connected
Communication Conditions
Signal level Conforms to RS-232C
Synchro system Tone pace synchro system
Transfer rate 9600 bps
Parity None
Data length 8 bit
Stop bit 1 bit
Flow control None
Command format
STX(02h) Command : Data ETX(03h)
Commands are 3 characters following STX, finally
adding ETX.
Add a : (colon) after the command as required, and
add the data.
Response formats
1. Setting command response
STX(02h) Command ETX(03h)
2. Query command response
STX(02h) Data ETX(03h)
3. Error response
STX(02h) Error code ETX(03h)
Error code
ER001: Invalid command
ER002: Parameter error