6.3. Reassenbly instructions
6.3.1. Attention when CF-T4H series is repaired
·
Please execute writing BIOS ID when you exchange the main board.
·
Parts (sheet and rubber) etc. related various the conductive cloth and heat spreader cannot be recycled. Use new parts.
6.3.2. Assembly knowhow of part LCD
LCD Rubber (Upper
LCD Rubber(Upper)
LCD Side Rubber
LCD Back Rubber(Lower)
LCD Front Case
LCD Front Case
Be parallel after putting
Big Small
LCD rubber, LCD side rubber and LCD backing rubber’s putting
LCD Frame Clamp
A red line of the cable is matched to the LCD frame externals.
0
1mm
Connector
1 2mm
1
2mm
PET Tape
LCD Insulation Sheet
LCD cable processing
Clamping processing of LCD cable, LCD connector connection and putting of PET tape of cable
The LCD insulation sheet is peeled off.
The LCD cable is processed to the LCD frame clamping.
The LCD cable is connected with the connector.
The PET tape is put.
Insulation Sheet of edge match
0
1mm
Connector of externals match
There must not be beginning to see from externals.
Conductive Cloth
(LCD Label)
Putting of the conductive cloth
The conductive cloth
is put and after putting a both side tape is put.
Process the part in the Signal line of the LCD cable in
the conductive cloth.
Put
the conductive cloth
on the connector surely.
LCD Insulation Sheet
Connector
Both Side Tape
LCD Cable
35