Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal *1 *3 *5 03h
Character *2 *4 *6
Parameters (*1, *2)
Mode
OFF 1 2 3 USER AUTO
IRIS
MANUAL IRIS DYNAMIC-GAMMA
Hexadecimal 30h 31h 32h 33h 34h 41h 4Dh 44h
Character 0 1 2 3 4 A M D
* When Mode is OFF—USER, parameters *3—*6 are not sent.
Example: When you set USER into Mode
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 34h 03h
Character A D Z Z ; O A I 4
* When Mode is AUTO IRIS or DYNAMIC GAMMA, parameters *5 and *6 are not sent.
Example: When Mode is AUTO IRIS and you set 3 into AUTO IRIS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 41h 33h 03h
Character A 3
Example: When Mode is MANUAL IRIS and you set 30 into MANUAL IRIS
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 4Dh 33h 30h 03h
Character M 3 0
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah *1 03h
Character O A I : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah *1 03h
Character A D Z Z ; O A I : *2
Parameters (*1, *2)
OFF 1 2 3 USER
Hexadecimal 30h 31h 32h 33h 34h
Character 0 1 2 3 4
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah *1 03h
Character O A I : *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 41h 49h 3Ah
Character A D Z Z ; O A I :
Hexadecimal 41h *1 03h
Character A *2
Parameters (*1, *2)
OFF 1 2 3
Hexadecimal 30h 31h 32h 33h
Character 0 1 2 3
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 41h 49h 3Ah 41h *1 03h
Character O A I : A *2
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
No No Yes Yes Yes Yes
2.38. DYNAMIC IRIS
2.39. DYNAMIC IRIS
2.40. DYNAMIC IRIS (AUTO IRIS)