Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 44h 03h
Character A D Z Z ; Q T D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 *7 03h
Character *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No No Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
0 1
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h
Character 0 0 0 0 0 0 0 1
4093 4094
Hexadecimal 34h 30h 39h 33h 34h 30h 39h 34h
Character 4 0 9 3 4 0 9 4
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is
returned.
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 44h 44h 03h
Character A D Z Z ; Q D D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 *7 03h
Character *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No No Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
300 301
Hexadecimal 30h 33h 30h 30h 30h 33h 30h 31h
Character 0 3 0 0 0 3 0 1
2045 2046
Hexadecimal 32h 30h 34h 35h 32h 30h 34h 36h
Character 2 0 4 5 2 0 4 6
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is
returned.
Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 54h 4Ch 03h
Character A D Z Z ; Q T L
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 *3 *5 *7 03h
Character *2 *4 *6 *8
Acceptability
SECURITY STNDBY NO SIGNAL SHUTTER TEST PATTERN REMOTE2
Yes No No Yes Yes Yes
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
211 212
Hexadecimal 30h 32h 31h 31h 30h 32h 31h 32h
Character 0 2 1 1 0 2 1 2
2046 2047
Hexadecimal 32h 30h 34h 36h 32h 30h 34h 37h
Character 2 0 4 6 2 0 4 7
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is
returned.
2.112. Query INPUT RESOLUTION — TOTAL DOTS
2.113. Query INPUT RESOLUTION — DISPLAY DOTS
2.114. Query INPUT RESOLUTION — TOTAL LINES