61/62
32 Thermosensor disconnected (IN) Intake air thermosensor is disconnected.
33 Thermosensor disconnected
(OPT)
Optical module (DMD) thermosensor is disconnected.
34 Thermosensor disconnected
(OUT)
Exhaust air thermosensor is disconnected.
35 Airflow sensor disconnected Airflow sensor is disconnected.
MAIN POWER ON
36 Air filter is blocked
37 Internal clock battery replacement The date is before December 31, 2005 or after January 1,
2036.
Sets the date after the
battery is replaced.
38 —
39 —
40 —
41 —
42 —
43 —
44 —
45 —
46 —
47 —
48 Fan error 1 Power unit fan
49 Fan error 2 Lamp fan 1
50 Fan error 3 Lamp fan 2
51 Fan error 4 Lamp fan 3
52 Fan error 5 Lamp fan 4
53 Fan error 6 Ballast fan 1
54 Fan error 7 Ballast fan 3
55 Fan error 8 Radiator fan
56 Fan error 9 Exhaust fan (C)
57 Fan error 10 Exhaust fan (L)
58 Fan error 11 Exhaust fan (R)
59 Fan error 12 R-DMD fan
60 Fan error 13 Liquid cooling pump (G)
61 Fan error 14 Liquid cooling pump (B)
62 Fan error 15 Color prism fan
63 Fan error 16 Lamp prism fan
64 Fan error 17 Ballast fan 2
65 Fan error 18 Ballast fan 4
Fan normal operation
66 Shutter error Shutter error Shutter ON/OFF
67 Dynamic iris error
68 Air filter unit error Air filter cleaning processing time-out Executes cleaning.
69 2.5 V DC error
70 3.3 V DC error
71 5.0 V DC error
The voltage is higher than 120% or lower than 80%. POWER ON
72 Lamp 1 uninitialization
73 Lamp 2 uninitialization
74 Lamp 3 uninitialization
75 Lamp 4 uninitialization
Lamp EEPROM is not initialized. Lamp EEPROM
initialization
76 Lamp 1 PFC error
77 Lamp 2 PFC error
78 Lamp 3 PFC error
79 Lamp 4 PFC error
80 FPGA1 configuration error
81 FPGA2 SXGA+ configuration error