56
PICTURE
FORMAT SMPTE
PULLDOWN MODE AUTO
COLOR MATCHING USER
:
MENU SELECT
:
CHANGE
MAIN MENU
PICTURE
POSITION
LANGUAGE
OPTION
TEST PATTERN
SIGNAL LIST
:MENU SELECT
ENTER:SUB MENU
To input BETACAM with YCbCr 480i
When receiving a picture of 480i with analog component signal YCbCr input, the input level of Cb and Cr can be
switched.
Press the “MENU” button.
The MAIN MENU screen will be displayed.
Select “PICTURE” with the
buttons.
Press “ENTER” button.
The PICTURE screen will be displayed.
Select “FORMAT” with the
buttons.
Switch the signal format with the
buttons.
• This toggles between SMPTE and BETACAM.
<Signal level>
Format
SMPTE
BETACAM
Y
700 mV
714 mV
Synchronous part
300 mV
286 mV
Cb , Cr
±350 mV
±504 mV
• This function is available only when input signals are supplied through the analog RGB input module
(ET-MD95RGB). RGB1, RGB2 inputs do not support BETACAM signals.
• This function can be switched only when receiving the picture of 480i in the YCbCr mode.
It cannot be switched when receiving the picture of signals other than RGB-REALITY mode, RGB
mode and 480i.
• SMPTE is the factory default.
Note
To set the sRGB compliant picture
sRGB is the international color reproduction standard (IEC61966-2-1) established by IEC (International
Electrotechnical Commission).
Perform the following setting procedure to reproduce the higher-fidelity picture in compliance with sRGB.
1. Set color matching adjustment to “OFF”.
2. Press the buttons on the “PICTURE” menu and select the “PICTURE MODE”.
Set to “NATURAL” with the buttons.
3. Select the “COLOR” with the buttons.
Press the STD (standard) button on the remote control to restore the factory default.
Follow the same procedure to restore the factory default for “TINT”, “COLOR
TEMP.” and “GAMMA”.
• sRGB is only enable when RGB signals are being input.
Note
Adjusting the picture