Panasonic PT-VW435NU Projector User Manual


 
-56-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0
Mode
IRIS control mode setting
0:APL control by the user menu
1:Fixed control
2:Off control
3:Life Test mode
0 0-3
1
Error Detect Enable Iris abnormality detection function 1 0-1
0:Enable, 1:Disable
2
Open Position Offset Open Position Offset -12 -511-511
3
Speed adjust switch speed setting 4/2 1-1023 AV/PC
4
Manual position adjust Iris(off) position setting 0 0-1023
5
APL Threshold Min APL Threshold Min data 0/4 0-255 AV/PC
6
APL Threshold Max APL Threshold Max data 128/12 0-255 AV/PC
7
Change APL Change APL 128/8 0-255 AV/PC
8
Change position Change position 0/520 0-1023 AV/PC
9
Speed adjust 2 close speed setting 4/2 1-1023 AV/PC
10
Close Limit Dimmer 0 Close Limit Dimmer 0 500/700 0-1023
11
Close Limit Dimmer 1 Close Limit Dimmer 1 500/700 0-1023
12
Close Limit Dimmer 2 Close Limit Dimmer 2 500/700 0-1023
13
Close Limit Dimmer 3 Close Limit Dimmer 3 500/700 0-1023
14
Close Limit Dimmer 4 Close Limit Dimmer 4 500/700 0-1023
15
Close Limit Dimmer 5 Close Limit Dimmer 5 500/700 0-1023
16
Close Limit Dimmer 6 Close Limit Dimmer 6 500/700 0-1023
17
Close Limit Dimmer 7 Close Limit Dimmer 7 500/700 0-1023
18
Close Limit Dimmer 8 Close Limit Dimmer 8 500/700 0-1023
19
Close Limit Dimmer 9 Close Limit Dimmer 9 500/700 0-1023
20
Close Limit Dimmer 10 Close Limit Dimmer 10 500/700 0-1023
21
Close Limit Dimmer 11 Close Limit Dimmer 11 500/700 0-1023
22
Close Limit Dimmer 12 Close Limit Dimmer 12 500/700 0-1023
23
Close Limit Dimmer 13 Close Limit Dimmer 13 500/700 0-1023
24
Close Limit Dimmer 14 Close Limit Dimmer 14 500/700 0-1023
25
Close Limit Dimmer 15 Close Limit Dimmer 15-18 500/700 0-1023
30
Update Interval 1 Update interval 1(unit:ms) 8/15 0-1023 AV/PC
31
Update Interval 2 Update interval 2(unit:ms) 8/1 0-1023 AV/PC
Group
230
VBI Slice Level
0 Generic Initial Slicing Level PW190 register 0xE344 50 0-255
1
Generic High Level Threshold
PW190 register 0xE345
-
0-255
* Read only
2
Generic Low Level Threshold
PW190 register 0xE346
-
0-255
* Read only
3
Generic Minimum Low Level
PW190 register 0xE347 30 0-255
4 Generic Maximum High Level PW190 register 0xE348 200 0-255
Group
250
FAN Control * Fan vollt-
age adjustment
0
FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
36 0-255
1
FAN1 MAX ADJUST (DAC)
220
0-255
2
FAN2 MIN ADJUST (DAC)
15
0-255
3
FAN2 MAX ADJUST (DAC)
210
0-255
4
FAN3 MIN ADJUST (DAC)
15
0-255
5
FAN3 MAX ADJUST (DAC)
210
0-255
6
FAN1 MIN ADJUST (DAC)
36
0-255
7
FAN1 MAX ADJUST (DAC)
220
0-255
8
FAN2 MIN ADJUST (DAC)
36
0-255
9
FAN2 MAX ADJUST (DAC)
220
0-255
10
FAN3 MIN ADJUST (DAC)
56
0-255
11
FAN3 MAX ADJUST (DAC)
220
0-255
12
FAN3 MIN ADJUST (DAC)
56
0-255
13
FAN3 MAX ADJUST (DAC)
220
0-255