Panasonic PT-VW435NU Projector User Manual


 
-57-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group
252
FAN Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land "On1", 2: Hi-
Land "On2"
- 0 - 2
* Read only
1 SAFETY SWITCH For test purpose 0 0,3-6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100 0-255
4 FAN2 MANUAL VOLTAGE 100 0-255
5 FAN3 MANUAL VOLTAGE 100 0-255
6 FAN4 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100 0-255
7 FAN5 MANUAL VOLTAGE 100 0-255
8 FAN6 MANUAL VOLTAGE 100 0-255
9 FAN7 MANUAL VOLTAGE 100 0-255
Group
253
Fan Tem Error Setting (Memorized)
(PT-VX505N/PT-VW435N)
Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0 Temp A Warning (High) 9999 -
1 Temp B Warning (High) 9999 -
2 Temp C Warning (High) 9999 -
3 Temp B-A Warning(High) 9999 -
4 Temp C-A Warning(High) 9999 -
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45 44 39/35 39/36 30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
64 63 54/50 54/51 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
65 65 56/58 56/59 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
28 28
24/22 24/22
0-100
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
21 21
18/16 18/16
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
49 48 39/36 39/37 30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
68 67 53/50 53/50 -
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
65 64 55/57 55/58 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
34 34
27/25 27/25
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
26 26
20/17 20/17
0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
10 0-100
17
Temp C Warning Offset
(Temp)
10 0-100
18
Temp B-A Warning Offset
(Temp)
100 0-100
19
Temp C-A Warning Offset
(Temp)
100 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-5
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
26 Temp A ForceLamp ECO 39 40 37/33 37/34 20-50
27
Temp A ForceLamp ECO EN-
ABLE
1 0-1
Group
254
Fan Control Range Setting (Temp./Voltage)
(PT-VX505N/PT-VW435N)
Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0
Normal Fan Control Min
Temp
30 31 26/26 25/26 20-100
1
Normal Fan Control Max
Temp
38 38 34/32 34/33 20-100
2 Normal Fan1 Min 62 62 82/102 82/102 0-255