Panduit DPOE24U1X Network Card User Manual


 
PANDUIT® DPoE™ Power Patch Panel User’s Guide Issue 2.2
Part Number: PN378A
34
Figure 5: Edit Panel Screen
TIP:
Prior to modifying any entries on this screen, click on the Refresh button to
retrieve the latest information stored in the specific panel.
This screen will allow the network operator to change the panel IP address, the panel attributes,
the SNMP setting, or the trap settings.
After any changes are made, be sure to click on the Save button to store the information and
transmit it to the DPoE™ Power Patch Panel.
Panel IP Address
The DPoE™ Power Patch Panels come with a factory setting of DHCP address
assignment. After the panel is connected to the EM, the network administrator may
change this setting by adding an IP address
& Subnet Mask, if desired, to be
consistent with the rest of his/her network. The Gateway
field is the IP address of a
gateway. If the EM and the
DPoE™ Power Patch Panels are on different networks
or if the SMTP server is on a different network from the panel, the panel will send
those messages to the gateway IP address specified.
NOTE:
The DPoE™ Power Patch Panel supports either static IP addressing
or DHCP address selection. If the panel is set for DHCP, no other
information is required in this section.
Panel Attributes
This portion of the screen can be used to set the Panel Name, Rack Name, Rack
Space Position, Panel Physical Location, and Power Supply Location. These fields
are freeform and, while these fields will not change the operation of the EM, they
allow the EM to present the panel and rack information in a user-friendly format. For
example, with these fields set, panels in the same rack will be grouped together in
the Tree View of the Network area on the system-level opening screen. Likewise,