Monitoring
6-17
9820-A2-GB20-20
June 2000
System and Test Status Messages
System and test status information is selected from the Status menu.
Main Menu
Status
System and Test Status
The following information is included on this screen:
H
Self-Test Results Messages
H
Health and Status Messages
H
Test Status Messages
Self-Test Results Messages
These self-test result messages appear in the Self-Test Results field at the top of
the System and Test Status screen.
Table 6-10. Self-Test Results Messages
Message
What It Indicates What To Do
Failure
xxxxxxxx
An internal failure occurred
(xxxxxxxx
represents an
8-digit hexadecimal failure
code used by service
personnel).
Record the failure code
before resetting the unit;
otherwise, the error
information will be lost.
1. Record the failure code.
2. Reset the unit.
3. Contact your service
representative.
Last Reset
(Model 9820-45M)
Date and time the unit was
powered on or reset.
No action needed.
Passed No problems were found
during power-on or reset.
No action needed.