Paradyne 9820-8M Computer Monitor User Manual


 
Configuration Options
4-38
9820-A2-GB20-20
June 2000
Table 4-11. Management PVC Options (3 of 4)
Primary DLCI
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the DLCI number used for the management PVC after the frame relay
interface is selected.
The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part
of a PVC connection or already assigned as a management PVC. For multiplexed
DLCIs, at least one EDLCI must be unconfigured for the DLCI.
NOTES: DLCI cannot be entered if the Link field is blank.
Clearing the Link also clears the DLCI.
16 – 1007 – Specifies the DLCI number (inclusive).
Primary EDLCI
Possible Settings: 0 – 62
Default Setting: Initially blank; no default.
Specifies the EDLCI number used for a management PVC when a multiplexed DLCI is
selected. EDLCIs identify individual connections within multiplexed DLCIs that are
unique to those DLCIs.
Use a unique EDLCI to identify an individual connection within a multiplexed DLCI.
Use 0 to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the
primary EDLCI for customer data, which has a higher utilization rate than management
data, with slightly less line overhead.
Display Conditions
– This option does not appear if the DLCI field does not reference
a multiplexed DLCI.
NOTE: Clearing the DLCI or changing it to a standard DLCI suppresses EDLCI
field.
0 – 62 – Specifies the EDLCI number (inclusive).
Primary Link RIP
Possible Settings: None, Proprietary, Standard_out
Default Setting:
For multiplexed DLCIs:
Proprietary
For nonmultiplexed DLCIs:
Standard_out
For Model 9820-45M:
None
Specifies which Routing Information Protocol (RIP) is used to enable routing of
management between FrameSaver units and attached equipment.
None – Does not use a routing protocol.
Proprietary – (Models 9820, 9820-2M, 9820-8M.) Uses a proprietary variant of RIP
version 1 to communicate routing information between FrameSaver units. A
FrameSaver unit must be on the other end of the link. This is the factory default for
management PVCs configured on multiplexed DLCIs (see Table 4-8, DLCI Record
Options).
Standard_out – The device will send standard RIP messages to communicate routing
information only about other FrameSaver SLV units in the network. This is the factory
default for management PVCs configured on standard DLCIs.
NOTE: The router must be configured to receive RIP on the port connected to the
FrameSaver unit for the management interface (e.g., Cisco: config-t,
router RIP, int serial
x
, IP RIP Receive version 1,
ctl-z WR). See
Setting Up So the Router Can Receive RIP
.