Paradyne 3825PLUS Network Card User Manual


 
C-13825-A2-GB30-20 November 1996
Technical Specifications
Table C-1
(1 of 2)
Model 3825
Plus
Technical Specifications
Specifications
Description
APPROVALS Refer to the label on your modem or contact your local sales representative.
COMPATIBILITY
AND VF DATA RATES
Dial-Line Modulations
Proprietary V.34 (33,600, 31,200 bps)
ITU-T V
.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800,14,400,12,000, 9600, 7200,
4800, 2400 bps)
V.32
terbo
(19,200, 16,800 bps)
CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
CCITT V.32 (9600, 4800 bps)
CCITT V.22bis (2400 bps)
CCITT V.22 (1200 bps)
CCITT V.21 (300 bps)
Bell 212A (1200 bps)
Bell 103J (300 bps)
Leased-Line Modulations
Proprietary V.34 (33,600, 31,200 bps)
ITU-T V
.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000, 9600, 7200,
4800, 2400 bps)
V.32
terbo
(19,200, 16,800 bps)
CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
CCITT V.32 (9600, 4800 bps)
CCITT V.22bis (2400 bps)
Fax Modulations
CCITT V.17 (14,400, 12,000, 9600, 7200 bps)
CCITT V.29 (9600, 7200 bps)
CCITT V.27ter (4800, 2400 bps)
DTE RATES 1
15,200, 76,800, 57,600, 38,400, 28,800, 19,200, 14,400, 12,000, 9600, 7200, 4800, 2400,
1200, 300 bps
ERROR CONTROL CCITT V.42
MNP 4–2
DATA COMPRESSION CCITT V.42 bis
MNP Class 5
C