Paradyne 8335 Network Card User Manual


 
3. Configuration
8335-A2-GB20-70 February 2003 3-23
4. Save the changes as prompted.
For . . . Enter . . .
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Remote Management Enable or Disable to enable/disable support for remote
management of devices on the SHDSL line from the STU-R
via the Embedded Operations Channel (EOC) (Default =
Enable).
Enable – Enables remote management support.
Disable – Disables remote management support.