3.3 CONNECTING THE TWISTED-PAIR LINE INTERFACE
The Model 1058 supports communication between two peer Ethernet
LAN sites over a distance of up to 4,652 ft (1,418 m) over 24 AWG (0.5
mm) twisted-pair wire.
Note
Actual distance and link performance may vary depending on
the environment and type/gauge of wire used.
Follow the steps below to connect the Model 1058 VDSL Interfaces.
Note
The Model 1058 units work in pairs. One of the units must be a
Model 1058/CO (Central Office), and the other unit must be a
Model 1058/CP (Customer Premise). It does not matter which
end is the 1058/CO and which is the 1058/CP. The link is always
initiated by the 1058/CP. As long as the 1058/CO is powered on,
the 1058/CP can establish a link by being powered on or by hav-
ing its power reset.
1. To function properly, the two Model 1058's must be connected
together using twisted-pair, unconditioned, dry, metal wire, between
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through
signal equalization equipment are not acceptable.
2. The Model 1058 is equipped with two interface jacks that can be used
on the VDSL interface, an RJ-45 or a terminal block. These VDSL
interfaces are a two-wire interface. Observe the signal/pin relation-
ships on the Model 1058's VDSL interface jacks.
The RJ-45 connector on the Model 1058's twisted pair interface is polar-
ity insensitive and is wired for a two-wire interface. The signal/pin rela-
tionship is shown in Figure 4.
Figure 4.
Model 1058 (RJ-45) twisted pair line interface.
The terminal block connector on the Model 1058's twisted pair interface
is polarity insensitive and is wired for a two-wire interface. The signal/pin
relationships is shown in Figure 5.
1 (no connection)
2 (no connection)
3 (no connection)
4 (2-Wire RING)
5 (2-Wire TIP)
6 (no connection)
7 (no connection)
8 (no connection)
1
2
3
4
5
6
7
8