16
APPENDIX A
SPECIFICATIONS
A.1 LAN CONNECTION
• Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• VDSL Connection:
RJ-45 and Terminal Block
A.2 TRANSMISSION LINE
Two-wire unconditioned twisted pair.
A.3 VDSL LINE RATE
12.5 Mbps, symmetric upstream/downstream.
A.4 ACTUAL DATA RATE
10 Mbps, symmetric upstream/downstream.
A.5 VDSL DISTANCE
4,000 ft (1,219 m)
A.6 VDSL SURGE SUPPRESSOR
Gas tube with maximum current surge: 20 kA (8120
µ
s).
A.7 LED STATUS INDICATORS
• Power (Green)
• VDSL: Link (Green) & Error (Red)
• Ethernet: Link (Green) & Activity (Yellow)
A.8 POWER SUPPLY
External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
• Power consumption: 450 mA at 5 VDC
A.9 TEMPERATURE RANGE
0–50°C
A.10 HUMIDITY
Up to 90% non-condensing.
A.11 DIMENSIONS
1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)