Patton electronic 2172A Switch User Manual


 
16
APPENDIX A
SPECIFICATIONS
A.1 LAN CONNECTION
Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
CopperLINK Connection:
Shielded RJ-45
A.2 TRANSMISSION LINE
Two-wire unconditioned twisted pair.
A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE
Line Rate: 50/50 Mbps, upstream/downstream. Additional five line
rates are available via DIP switch settings.
Distance: 4,250 ft (1.3 km) at 1 Mbps upstream/4 Mbps downstream
Note
Distances depend on selected line rate and line conditions. See
Appendix D on page 19 for details.
A.4 LED STATUS INDICATORS
Power (Green)
CopperLINK: Link (Green)
Ethernet: Link (Green) & Activity (Flashing Green)
Remote (Green)
Local (Green)
A.5 POWER SUPPLY
External AC and DC options:
AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
DC: 12 VDC, 24 VDC and 48 VDC
Power consumption: 860mA at 5V
A.6 TEMPERATURE RANGE
0–40°C
A.7 HUMIDITY
Up to 90% non-condensing.
A.8 DIMENSIONS
1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)