Patton electronic 3060/V24 Network Router User Manual


 
3060/V24
102001UA
2-1
SETUP & INSTALLATION
PATTON ELECTRONICS CO.INSTALLATION AND OPERATIONS MANUAL
Caution, Disconnect the POWER Before Removing The Cover
Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.
CHAPTER 2 - SETUP AND INSTALLATION
Power Connection
Before connecting the 3060/V24 (CTS MD-V.24/TCB) to a AC power source the top cover
must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/
220VA voltage switch, turn the switch with a
coin or screw driver to the appropriate
voltage for your country. EXAMPLE: In the
United States of America; set to 110VA.
The unit is supplied with a IEC power
connector next to the voltage select
switch, plug the power cord into the
connector until it is firmly seated. You
may now connect the power cord into
your AC outlet.
Factory Configuration Switch Settings
The 3060/V24 (CTS MD-V.24/TCB) is configured prior to shipment with the switches set to the
following default positions:
Switch 21 - 1,2,3 and 8 to
OFFOFF
OFFOFF
OFF, 4, 5, 6 and 7 to
ONON
ONON
ON.
Anti-Stream timer = 2 M bits
TX Clock Source = Master pin 15
Chassis Ground not connected to Signal Ground
Switch 22 - 4 and 5 to
OFFOFF
OFFOFF
OFF, 1, 2, 3, 6, 7 and 8 to
ONON
ONON
ON.
CTS Delay = 0
Internal Baud Rate = 9600
Sync Mode
Switch 23 - 1, 2, 3 and 4 to
OFFOFF
OFFOFF
OFF, 5 and 6 to
ONON
ONON
ON.
No Data Time Out = 2048 bits
Anti-Stream = Disabled
Broadcast Data to Sub-Channels
Fallback Clock = Disabled
Fallback Clock Source = Data Transitions
WARNING: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE ONLY
WITH SAME TYPE AND RATING FUSE.
110 / 220VA Switch
Fuse Drawer
PORT 4 MASTER DTE/ DCE
IEC Power Connector
110