SmartLink M-ATA Getting Started Guide 6 • System
Conditional Call Forwarding Timer
Specified a time period as a call forward condition. After the number of seconds specified, the conditional call
forwarding process will be performed.
Warm Line Delay
Specify a time period as a delay time for warm line dialing. If warm line is enabled, then the SmartLink M-ATA
will wait this amount of time after the handset is off-hook before dialing the warm line phone number.
Interdigit Timer
The number of seconds the SmartLink M-ATA will wait for the caller to input a subsequent digit of the dialed
number. If the timer value is exceeded before the dial plan is matched (see section “Gateway Settings” on
page 37), the busy tone will be played to the caller.
Offhook Idle Time
If the handset is off-hook with no dialing activity for longer than the time specified, then the busy tone will be
played. The default is 6000 ms (6 seconds).
Offhook Warning tone time
If the handset is off-hook with no dialing activity for longer than the time specified, then the off-hook warning
tone will be played. The default is 12000 ms (12 seconds). This value should be greater than the off-hook
idle time (see section “Offhook Idle Time”).
FXS Port
Choose the correct country for a proper impedance match.
Figure 37. FXS Port Polarity Configuration section of Localization window
FXS port Input Gain
Adjust the input gain level for FXS port.
FXS port Output Gain
Adjust the output gain level for FXS port.
Caller ID Method
Specifies the country-specific Caller ID format.
“Call Progress Tones” Synchronization
When “Call Progress Tones” Synchronization is selected, the Caller ID presentation method value is used to auto-
matically set the county-specific call progress tones.