Paxar 9413 Printer User Manual


 
E3. "string 1" Terminator for status requests and ENQ requests. Up to any 3
digits in the 0 to 255 decimal range. The tilde (~) must be
used with decimal characters. The default is "013". Sending
"" disables this sequence.
E4. "string 2" Terminator for job requests and data uploads. Up to any 3
digits in the 0 to 255 decimal range. The tilde (~) must be
used with decimal characters. The default is none. Sending ""
disables this sequence.
After you change these parameters, all packets, including any
future configuration packets, must use the new control characters.
Monarch recommends using the tilde and ASCII character code
sequence when sending this packet multiple times. Also, set the
packet delimiters to characters within the 21 hex to 7E hex range.
You must send the control characters packet to enable the
immediate commands. An immediate command will execute
immediately, even if it is embedded within quotation marks, and
all data following the command in the string will be ignored.
Example
{I,E,"~123~063~034~124~125~126~094" p }
Changes the parameter separator character from , to ?. The
other control characters remain unchanged. It also enables the
immediate commands by defining the ^ symbol as the command
identifier.
Resetting Control Characters
You can change the characters in the previous example back to
their original settings by downloading this packet:
Example
{I?E?"~123~044~034~124~125~126~094" p }
Notice that the parameter separator is ? in this packet. This is
the parameter separator that was set before this packet. Once
the packet is received by the printer, the new parameter separator
(a comma, in this case) is valid.
3-14 Configuring the Printer