Pelco C581M-B Computer Keyboard User Manual


 
20 Pelco Manual C581M-B (1/04)
PASSWORD
You can program the multiplexer to request a password for access to programming menus.
The password is enabled in the Advanced System Setup menu (refer to the
Advanced
System Setup
section).
The universal password is 3916 and cannot be changed. This password must be entered
whenever one is requested. The password is entered from the keyboard by pressing each
number followed by pressing the CAM key: 3, CAM, 9, CAM, 1, CAM, 6, CAM.
MENUS
To program from the keyboard you have to be in main monitor mode. Press the MAIN
MONITOR key.
SYSTEM SETUP (View Key)
To program the main basic system parameters:
1. Press the MAIN MONITOR key.
2. Use the number keypad to enter the address of the multiplexer (1-16 if the keyboard is
connected to a multiplexer; 1-8 if the keyboard is connected to a server), then press
the UNIT key.
3. Press the VIEW key for approximately three seconds. Type the password, if requested.
The password must be entered by pressing each number key followed by pressing the
CAM key. The System Setup menu appears. The currently selected menu item blinks.
4. Use the pan/tilt keys to move between items on the screen. When the menu item you
desire is highlighted (blinking), do one of the following:
If a menu item has more than one option, press the OPEN key to cycle through
the options to select the one you want.
If a menu item has only one option, press the OPEN key to select it.
Time and Date
Set the current time and date. The time uses a 24-hour clock.
Time Display
ON - Displays the time on the main monitor.
OFF - The time is not shown on the main monitor.
TIP:
Once you are in a
menu, you can go to another
menu by pressing the key(s)
for that menu. Press and
release the VIEW key to
switch to the system setup
menu. Enter a camera
number and then press and
release the CAM key to
change to a camera menu.
Press and hold the SEQ and
LIVE/VCR keys to switch to
the sequence and record
menus.
TIP:
In any menu you can
scroll the options forward by
pressing the OPEN key or
scroll backward by pressing
the CLOSE key.
Figure 3. Basic System Setup Menu
2/6/8 Hr
2/6/8 Hr
MAIN MONITOR VIDEO
RESET ACTIVITY DETECTION ALL CH TO
*2,6,or 8 Hr 120 Hr
12 Hr 168 Hr
16 Hr 180 Hr
18 Hr 240 Hr
24 Hr 360 Hr
48 Hr 480 Hr
72 Hr 600 Hr
84 Hr 720 Hr
96 Hr 960 Hr
HIGH RESOLUTION
REDUCED FLICKER
MAIN MONITOR DISPLAY HIGH RESOLUTION
**
* 2/6/8 HR FOR NTSC/EIA MODEL MULTIPLEXERS, 3 HR FOR PAL/CCIR MODELS.
REMAINING RECORD SPEEDS DEPEND UPON VCR MODEL.
** NOT SHOWN ON DUPLEX MONOCHROME MODELS OR SIMPLEX MULTIPLEXERS
**