Pelco REL2064 Network Card User Manual


 
18 C1518M-A (11/02)
Figure 11. REL2064 Dimension Diagram
19.00 (48.26)
PWR
ALARM
REL2064
Relay Interface Unit
Made in USA
17.40 (44.20)
1.75
(4.45)
8.15
(20.70)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES
00695
SPECIFICATIONS
ELECTRICAL
Input Voltage: 100-240 VAC, 50/60 Hz, auto-ranging
Power: 30 VA
Data Ports
Diagnostic: RS-232, DB9 connector
Input: RS-485, RJ-45 connector
Output: RS-485, RJ-45 connector
Indicators: Two green power LEDs
One data LED
Fusing: 500 mA, 250V
Relay Contacts
Type: Normally open
Max. Switching Capacity: 60 watts
Max. Operating Voltage: 125 VAC/VDC
Maximum Current: 2 amps
Contact Resistance: 75 milliohms
Rated Load Parameters: .5A @ 125 VAC; 2A @ 30 VDC
Relay Output: Load rating for relay contacts: 0.50A at 125 VAC or 1A at 25 VAC
GENERAL
Dimensions: See Figure 11.
Operating Temperature: 32° to 122°F (0° to 50°C)
Unit Weight: 8 lb (3.63 kg)
MECHANICAL
Connectors
Relay Inputs: Screw terminals
Power: 3-wire receptacle, #18 AWG
RS-485: Two RJ-45 connectors
RS-232: One DB9 connector (factory use only)
(Design and product specifications subject to change without notice.)