10
OPERATION
PowerLight Model 1250 and 1250DR
Flashing Rate:
The unit recharges quickly, as indicated by the READY light on the control panel. A
quick series of flashes can be obtained within the limits of the recharge time. Continuous
rapid flashing, however, can overheat and damage the flashtube and internal parts. The
maximum recommended rate of flashing depends upon the power level being used and
the amount of operation time. Use the following chart to serve as a guide for the
maximum rate to use in your situation.
Power
Level
Full
1/4
1/32
Operating
Time
Continuous
30 minutes
3 minutes
Continuous
30 minutes 3
minutes
Continuous
Sec.Between
Flashes.
15
6
4
6
3
2
1.5
Number of
Flashes.
Continuous
300
45
Continuous
600
90
Continuous
Exposure Information:
The following charts give the BCPS output for various umbrellas and reflectors.
Coverage angle is given in degrees.
Umbrella
Coverage
Full Power
Half
Quarter
Eighth
Sixteenth
Thirty-Second
32 inch
120 degree
5500
2750
1375
688
344
172
45 inch
120 degree
5583
2792
1396
698
349
174
60 inch
120 degree
5583
2792
1396
698
349
174
Reflector
Diameter
Coverage
Full
Half
Quarter
Eighth
Sixteenth
Thirty-Second
GN@ ASA 100
None
360°
2333
1167
583
292
146
73
110
7 1/2”
35°
25000
12500
6250
3125
1562
781
365
14”
40°
17500
8750
4375
2188
1094
547
305
16”
60°
23333
11667
5833
2916
1458
729
350
20”
65°
16333
8167
4083
2042
1021
510
295
24”
145°
4200
2100
1050
525
262
131
150