8
PowerLight Models 1250DR and 2500DR
Flash Power:
Use the Adjust button to turn on the Flash ws red LED. Adjust the PowerLight 1250DR
or 2500DR Flash power setting using the 1/2 or 1/10 f-stops UP/DOWN arrow buttons.
Ready Light:
The PowerLight 2500DR is fully charged when the READY lamp is on. Lowest power
(32ws) charge time is a maximum of .8 seconds and at full power charge (1000 ws) time
is a maximum of 3 seconds. The unit may be flashed before fully charged.
The PowerLight 1250DR is fully charged when the READY lamp is on. Lowest power
(16ws) charge time is a maximum of .5 seconds and at full power charge (500 ws) time is
a maximum of 1.5 seconds. The unit may be flashed before fully charged.
Modeling Light:
The modeling light has three modes of operation:
1. MANUAL [press the ADJUST button to turn the MODEL yellow LED on] adjusts
the modeling lamp intensity using the 1/2 or 1/10 f-stops UP/DOWN arrow buttons.
Pressing the MANUAL button a second time will change the mode to flash
adjustment and is indicated by the illuminated red LED
2. TRACK mode causes the modeling lamp intensity to track the FLASH setting. The
modeling lamp may be set to full intensity at any FLASH value, by simply pressing
the TRACK/SET button a second time, with the FLASH already set to desired watt-
seconds. Setting is retained when user returns from another mode.
3. FULL ON/OFF is exactly what it says. Press the FULL ON/OFF button to turn the
modeling lamp OFF (LED off) or ON (LED on).
All mode settings are retained, even after the power has been turned off.
tm
2
1
1
1
0
tm