6
Power Switch:
The power switch controls the AC power to both the modeling and flash circuits. You
have the option to turn-off the modeling circuit independently.
PowerLight Model PL1250
Flash Power:
All settings and controls of the PowerLight 1250 are extremely stable and repeatable due
to the use of an internal microcomputer. The 1250 and 1250DR are adjustable from
16watt seconds to 500 watt seconds.
To adjust the PowerLight 1250 to its lowest flash power setting (16 watt seconds), slide
the FLASH control knob all the way to the left.
To adjust the PowerLight 1250 to its greatest flash power setting (500 watt seconds),
slide the FLASH control knob all the way to the right.
To adjust the PowerLight 1250 to an exact flash power setting, use the accessory digital
display.
Ready Light:
The PowerLight 1250 is fully charged when the READY lamp is on. Lowest power
(16ws) charge time is a maximum of .5 seconds and at full power charge (500 ws) time is
a maximum of 1.5 seconds. The unit may be flashed before fully charged.
tm
tm