Planar C3012T Personal Computer User Manual


 
Boot Failures
The System BIOS attempts to display an error message on the display and halts when it
encounters the following error conditions.
1. Fixed disk error
Causes:
No drive connected
Configured for 0 cylinders
Controller reset failed
Drive not ready
Track 0 seek timed out
Drive initialization failed
Drive recalibration failed
Last track seek failed
2. CMOS checksum failed
Causes:
CMOS checksum failed
3. Timer error
Causes:
System timer (0) failed
4. I/O error
Causes:
I/O conflicts exist for serial and parallel ports, hard disk (any or all)
5. Over Temperature Error
Causes:
Internal temperature exceeded 50˚C causing the system to shut down
6. Other error
Causes:
Peripheral components IRQ conflicts
The System BIOS prints an error message but does not halt when it encounters the following
error conditions.
1. RTC error
Causes:
RTC lost power
2. CMOS error
Causes:
RTC battery failed
3. Configuration error
Causes:
User BIOS Extension Region X will exceed DFFFFH
Appendix C: Troubleshooting 37
CS Manual LAYOUT#1787 3/9/98 5:33 PM Page 37