Planar PD8130 Projector User Manual


 
Operation
Planar PD8130/PD8150 Installation/Operation Manual 61
PREL
I
MINA
R
Y
Lamp Hour Reset: When you replace the projector lamp (refer to Lamp
Replacement on page 63), you should also reset the lamp hour counter. To do
this, select Lamp Hour Reset from the Service menu, then press ENTER. Press
ENTER again to confirm the reset. Or, to cancel the operation, press on the
remote to highlight No, then press ENTER.
Factory Reset: Select Factory Reset from the Service menu to restore all
projector settings – except those listed below – to their factory-default values:
•Lamp Hours
User Memory 1 / User Memory 2
•ISF Day
•ISF Night
Model Name / Serial Number
•Language
Blue Only: This feature removes all red and green color information from the
image, and is useful for color-calibrating the projector or other video
components.
Test Patterns: The PD8130/PD8150 has numerous internal test patterns that are
useful to technicians for advanced calibration, measurement and fault isolation
purposes. To access them, select
Test Patterns from the Service menu and set it
to On.
The available test patterns are:
•White
•Black
•Red
•Green
•Blue
•Cyan
•Magenta
Yellow
ANSI Checkerboard
Horizontal Gray Ramp
•Focus Grid
Press or on the remote control unit or built-in keypad to cycle through the
test patterns.
Reset the Lamp Hour counter ONLY after you replace the
lamp. Otherwise, the reported “Lamp Hours” will be
inaccurate.
Do not exceed the recommended lamp life. An old lamp
becomes increasingly fragile and prone to sudden failure.
Note
W
ARNING