Polycom 1725-36032-001 Server User Manual


 
SpectraLink 8000 SVP Server: Administration Guide for SRP
PN: 1725-36032-001_G.doc
34
system function and to troubleshoot areas that may be experiencing
trouble.
Error Status
The Error Status screen displays any alarms that indicate some system
malfunction. Some of these alarms are easily remedied and others
require a call to Polycom’s Customer Support Department.
From the
System Status Menu, select Error Status. The screen displays
active alarms on the SVP Server.
The following table displays the list of alarms and a description of the
action to take to eliminate the alarm.
Alarm Text Action
Maximum payload usage reached Reduce usage, clear alarm
Maximum telephone usage reached Reduce usage, clear alarm
Maximum access point usage reached Reduce usage, clear alarm
Maximum call usage reached Reduce usage, clear alarm
SRP audio delayed Reduce usage, clear alarm
SRP audio lost Reduce usage, clear alarm
No IP address Configure an IP address
SVP Server(s) lost
Reduce usage or replace lost
SVP Server. Clear alarm
Press C to clear all clearable alarms.
Network Status
The SVP Server is connected to the Ethernet network, referred to as
the LAN or Local Area Network. The information about that
connection is provided through the
Network Status screen.