Polycom KWS1500 Server User Manual


 
KIRK Wireless Server 1500 Installation and Maintenance
Multi Cell Environment
In a multi cell environment, up to 3 Repeaters may be synchronized to a single Base
Station to extend the radio coverage.
Jump Configuration
Repeaters may also be configured in a “jump” configuration. In this configuration the
Repeater closest to the Base Station is the only Repeater in the chain that is synchronized
to the Base Station. Subsequent Repeaters are synchronized to the previous Repeater in
the chain.
Radio coverage overlap
Other factors involved in a deployment relate to radio coverage overlap. A coverage
overlap occurs when the radio fields of multiple Base Stations overlap each other. Base
Stations must be placed in such a way that the radio coverage from one Base Station to
another overlaps by 9 to 14 meters / 30 to 45 feet. An overlap is required so that as the
72160400_issue_B 10