KIRK Wireless Server 1500 Installation and Maintenance
Base Station cable wiring
5.7 Base Station and Repeater Installation
Mounting Base Stations
1. Terminate the Base Station cable to a suitable connection point such as a punch-down
block or patch panel.
2. Terminate the system end of the twisted-pair cable to a suitable connection point
such as a punch-down block or patch panel located close to the termination of the
Base Station cable.
3. Cross-connect the Base Station cables to the desired Base Station circuit. Power for
the Base Station is provided by the KWS1500 and is delivered via the cable to the
Base Station.
After the physical connection is made, the LED in the center of the Base Station will
flash. This indicates that the Base Station is receiving power from the KWS1500.
Once the Base Station synchronizes with the KWS1500, the LED will light steady.
4. Base Stations are not polarity sensitive. To mount the Base Station, drill two holes. If
mounting to a wooden surface, secure using some suitable screws. If mounting to a
brick wall, the holes should be drilled with a 6 mm diameter drill bit. Insert wall
plugs, and then secure using two suitable screws.
5. Each Base Station has an RJ-11 four-wire socket located on the base. Crimp an RJ-11
connector to the twisted-pair cable, using the center pair of pins.
72160400_issue_B 37