Polycom KWS1500 Server User Manual


 
KIRK Wireless Server 1500 Installation and Maintenance
sufficient pressure to the right side of the expansion card, and make sure that the
plastic stand-off pins click into place.
6. Carefully remove the DB25 blank panel on the rear of the KWS1500, and replace it
with the expansion board DB25 connector. Use the two supplied screws to secure the
DB25 connector to the KWS1500 case.
7. Connect and secure the KIRK Expansion Board 1500 cable.
8. Replace and secure the top cover.
9. Cross-connect Base Stations 8 to 15 to the new DB25 connector.
10. Power up the KWS1500 and make a cable delay measurement for all new Base
Stations added to the solution.
5.5 Installing KIRK Analog Interface Cards
Analog interface cards connect directly to the host PBX via standard analog lines. Each
handset is assigned to a single analog interface card channel, thereby obtaining a direct
link to the host PBX.
Each handset requires a single, unique, analog line connection to the host PBX to provide
a unique extension number per handset.
Each analog interface card supports up to eight analog lines, and therefore eight
handsets.
Analog interface cards must be installed from right to left (slots 0 to 7) in the
KWS1500.
Do not remove the top cover while the unit is connected to a power source.
Failure to disconnect the unit from the power source while the top cover is
removed can cause severe electric shock, damage to electrical components,
and even death.
1. Disconnect the KWS1500 from AC power.
2. Remove the top cover of the KWS1500 by removing the eight screws securing the
cover. There are two screws on each side of the unit and four on the rear.
3. Using a flat-blade screwdriver and a pair of needle-nose pliers, gently pry and
remove the metal punch-out to provide access to the expansion slot.
4. Remove the KIRK Analog Interface Card from its protective anti-static bag and insert
it securely into the expansion slot.
5. Use the supplied screws to secure the DB25 connector to the KWS1500 case.
6. Connect and secure the KIRK Analog Interface Card cable.
7. Replace and secure the top cover.
Cross-connect the KIRK Analog Interface Card to the provided single
line analog PBX lines.
72160400_issue_B 35