Printek 8000 Printer User Manual


 
P R I N T E R C O N F I G U R A T I O N
53
Baud Rate
Baud Rate
9600
Possible Values: 110, 150, 300, 600, 1200, 2400, 4800, 9600*, 19200
This item selects the baud rate for the serial interface. This must be set to
match the baud rate setting on the host computer.
Data Bits
Data Bits
8
Possible Values: 8*, 7
This item selects the number of data bits in the serial character frame. This
must be set to match the character size setting on the host computer.
Stop Bits
Stop Bits
1
Possible Values: 1*, 2
This item sets the number of stop bits to be used at the end of the serial
character frame. This must be set to match the stop bit setting on the host
computer.
Parity
Parity
None
Possible Values: None*, Even, Odd
This item Selects the parity checking requirements for the serial data bits.
This must be set to match the parity setting on the host computer.
Busy Signal Polarity
Busy Polarity