5 – Fibre Alliance MIB Objects
59047-03 B 5-45
A
connUnitPortName (1.3.6.1.3.94.1.10.1.17)
A user-defined name for this port. This means that up to DisplayString characters
may be supported. If less than, then the name will be truncated in the connunit.
Syntax
INTEGER
Access
read-write
Status
mandatory
Return Value
The symbolic port name. A 1G or 2G only capable port, would return port
followed by the port number. 10G ports would return 10G followed by the port
number. For example, a 1G/2G port#2 would return 'Port2' and a 10G port#18
would return '10G-18' by default.
connUnitPortPhysicalNumber (1.3.6.1.3.94.1.10.1.18)
This is the internal port number this port is known by. In many implementations,
this should be the same as connUnitPortIndex. Some implementations may have
an internal port representation not compatible with the rules for table indexes. In
that case, provide the internal representation of this port in this object. This value
may also be used in the connUnitLinkPortNumberX or connUnitLinkPortNumberY
objects of the connUnitLinkTable.
Syntax
INTEGER
Access
read-only
Status
mandatory
Return Value
The physical port number.