Q-Logic SANBOX2 Switch User Manual


 
5 – Fibre Alliance MIB Objects
5-108 59047-03 B
A
Table 5-34 lists the possible trap strings returned for the connUnitEventDescr
variable.
Table 5-33. connUnitEventDescr Variable Field Descriptions
connUnitEventDescr Variable Description
Tag # The number that identifies the event.
Event # The event counter.
Chassis The switch on which the event occurred.
Blade The I/O blade on which the event
occurred.
Port The port on which the event occurred.
TimeDate The time stamp of the event.
Module The software module where the event was
initiated.
Addr The address in the software module where
the event was initiated.
Descr The description of the event.
Table 5-34. connUnitEventDescr Trap List
Trap Type Filter Level Notification
connUnitPortStatusChange eventSeverity_info,
eventSeverity_info,
eventSeverity_critical,
eventSeverity_info
UserPort.ConfigChange,
UserPort.StateChange,
Eport.ConvergeAlarm,
UserPort.OperChange
connUnitDeletedTrap eventSeverity_info,
eventSeverity_info,
Fabric.OperChange,
Eport.OperChange
connUnitStatusChange eventSeverity_info,
eventSeverity_info,
eventSeverity_critical,
eventSeverity_info
Switch.OperChange,
Switch.StateChange,
Switch.ResetAlarm,
Chassis.OperChange