Q-Logic SANBOX2 Switch User Manual


 
6 – Fabric Element MIB Objects
6-16 59047-03 B
A
fcFxPortPhysLastChange (1.3.6.1.2.1.75.1.2.2.1.3)
The value of sysUpTime at the time the FxPort entered its current operational
status. A value of zero indicates that the FxPort's operational status has not
changed since the agent last restarted.
Syntax
TimeStamp
Access
read-only
Status
current
Return Value
Unsupported. Always returns error status "NoSuchName".
fcFxPortPhysRttov (1.3.6.1.2.1.75.1.2.2.1.4)
The Receiver_Transmitter_Timeout value of the FxPort. This is used by the
receiver logic to detect a loss of synchronization.
Syntax
Milliseconds
Access
read-write
Status
current
Return Value
The default RT_TOV parameter is: 100 (0x64). This is a global setting for the
switch. If writing value to a port, all ports will reflect this new value.
Diagnostic testing (3)
Down linkfailure (4)
Table 6-6 fcFxPortPHysOperStatus Return Values
Status Return Value