CHAPTER 3. LEASED LINE OPERATION
ACTIVE Professional External Modem Users Manual
10
Then press the
Enable
Switch to update the DTE speed, The character U is
shown on the LED segment.
If more setting are required (i.e transmission mode, flow control, etc), repeat
the above procedures.
4. Enable the POLL after all parameters are set.
Method:
Set
Normal / Config.
Switch to PUSH position for Config mode.
Toggle the
Menu
Switch to Menu 2 (type of line menu), the digit ‘2’ is shown
on the LED segment.
Then toggle the
Function
Switch to Function 1 (2 wire LL is selected), the
digit ‘1’ is shown on the LED segment.
Then press the
Enable
Switch to enable POLL, the character U is shown on
the LED segment and all parameters will be saved to profile 0 automatically.
5. To finish configuration by setting the
Normal / Config.
Switch to POP
position.
You will hear the sound of modem handshaking procedure. The sound will be
on until the data connection is made.
Procedure to exit the Power-On Leased Line(POLL)
1. Set
Normal / Config.
Switch to PUSH position for configuration mode.
2. Toggle the
T/D
switch to break the handshake.
3. Toggle the
Menu
Switch to Menu 2 (type of line menu), the digit ‘2’ is shown
on the LED segment.
4. Toggle the
Function
Switch to Function 0 (dial up line is selected), the digit
‘0’ is shown on the LED segment.
5. Press the
Enable
Switch to disable POLL, the character U is shown on the
LED segment and all parameters will be saved to profile 0 automatically.
AT COMMAND for Leased Line Configuration
AT%On * Select answer/originate mode Default : 1
%O0 Selects answer mode
%O1 Selects originate mode
AT&Ln * Transmission line type Default : 0
AT&L0 Dial-up line
AT&L1 2-wire Leased line (Option)
AT%Rn * Select Receive sensitivity level Default : 0
AT%R0 Select 43dBm receive sensitivity level