Renesas M306NKT3 Network Card User Manual


 
M306NKT3-RPD-E User’s Manual 3. Usage (How to Use the Emulator Debugger)
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006 Page 54 of 104
Specifying the communication interface (LPT
communication)
- For selecting the LPT communication, click the radio button “LPT” of
the MCU tab.
- For the Type area, specify the LPT interface communication mode to be
used.
- Specify the I/O address of the parallel port at the I/O address area.
- For BIOS setup, the following addresses are available.
- 378h
- 278h
Specifying the communication interface (USB
communication)
- For selecting the USB communication, click the radio button “USB” of
the MCU tab.
- The emulators connected by USB cable are shown at Serial No. area.
- Select the serial No. of the emulator you are going to connect.
3) Executing the self-check
Executing the self-check
Enable this function when you want the emulator to be self-checked at
startup. Be sure to select the check box only when you want the emulator to
be self-checked at startup.
Note:
In case where self-checking was normally completed, terminate the
emulator debugger once, then start operation with no self-checking
carried out again (with leaving the check box unchecked).
This function may be enabled in the following cases:
- When you are using the emulator you have just purchased.
- When you successfully download the firmware, but fail to start up the
emulator debugger.
- When you want to confirm whether the emulator is operating normally
because, for example, the MCU runs out of control or something is
wrong with the trace results.
This function can be enabled only when you are starting up the emulator
debugger.