RF-Link Technology NL6000 Network Card User Manual


 
RF Neulink
NL6000 User Guide
18
Figure 8 shows the use of a wildcard (12FF) to transmit data to multiple
units within range of Unit #1 that have a MYID starting with 12
Figure 8: Addressing with Wildcards
Figure 9 shows the use of a wildcard (FFFF) to broadcast data to all units
within range of Unit #1.
Figure 9: Using Wildcards to Broadcast
5.5. Behavior of Repeater Units
When configured as a repeater, the unit listens for packets that qualify for
repeating in addition to its normal functions. A unit qualifies a packet for
repeating based upon the TOID or MYID value associated with the
packet. The trigger for repeating a packet from a base station to a remote
is the value in the packets TOID field. The trigger for repeating a packet
from a remote to a base station is the value in the packets MYID field.
You can establish up to eight triggers for each repeater unit.