RF-Link Technology NL6000 Network Card User Manual


 
RF Neulink
NL6000 User Guide
28
6.1. General Procedures
Entering Programming Mode
Perform this procedure when you need to reset any of the existing
configuration parameters for the NL6000.
Note:
If the
Programming Mode
is
Disabled
, you must perform
this procedure within five seconds of powering on the unit.
1. Open
HyperTerminal
or
Procomm
.
2. Type
…//
The
Main Menu
opens.
Setting the Program Mode
The
Program Mode
parameter determines when the operator can enter
programming mode from operational mode.
1. Select
Serial
ä
Program Mode
.
2. Select from the following options:
1-Disabled
Enter programming mode within five seconds of power-on.
Select this option under normal operating conditions to
prevent accidental resetting of parameters.
2-Enabled
Enter programming mode whenever you type the key
sequence
…//
. There must be a pause before and after the
sequence. Select this option during factory configuration or
during initial configuration of a unit.
Saving Configuration Changes to Flash Memory
Select
E - Exit
from the
Main Menu
to save the updated parameter settings to
the units flash memory. The unit immediately begins using the new
configuration.
Saving Configuration Changes Temporarily
Select
C - Continue
from the
Main Menu
to temporarily save the updated
settings for the current operating session. The configuration is not saved to
flash memory. You can revert to the prior configuration by cycling power to the
unit.
Reverting to the Prior Configuration
Select
R - Restart
from the
Main Menu
to ignore the changes you made and
revert back to the prior configuration.