Laser Facsimile
- 27 -
5 - Parameters/Setup
Language
This setting enables you to choose the menu language of
your choice. By default, the multifunction machine is set
to English.
To select the language:
203 - SETUP / GEOGRAPHICAL / LANGUAGE
1 Press , enter 203 using the keypad. Confirm with
OK.
2 Select the required language using and ,
then press the OK button to confirm.
3 To exit this menu, press .
Local prefix
This function is used when your fax is installed with a
private network, behind a company’s PABX. It allows you
to program an additional automatic local prefix (to be
defined), enabling you to automatically exit the
company’s telephone network system, but only under
certain conditions:
• the company’s internal numbers, where a prefix is not
required, must be short numbers less than the
minimal size (to be defined, for example France has
10 digits),
• the outside numbers requiring a prefix, must be long
numbers greater or equal to the minimal size (to be
defined, for example France has 10 digits).
Programming your fax with the local prefix consists of two
steps:
1 defining the minimal size (or equal) of the
company’s outside numbers,
2 defining the outgoing local prefix of the company’s
telephone network. This prefix will automatically be
added as soon as an external number is dialled.
252 - SETUP / TEL. NETWORK / PREFIX
1 Enter the required minimal SIZE NUMBER of the
company’s outside numbers and confirm with OK.
The minimal size will range between 1 and 30.
2 Enter the required outgoing local prefix of the
company’s telephone network (maximum 5
characters) and confirm with OK.
Transmission report
You may print a transmission report for all
communications over the telephone network (STN).
You may choose between more than one criteria for
printing reports:
• WITH: a report is given when the transmission was
properly performed or when it is completely
abandoned (but there is only one report per request),
• WITHOUT: no transmission report, however, your fax
will note all transmissions that took place in its log,
• ALWAYS: a report is printed with each transmission,
• ON ERROR: a report is printed only if the transmission
failed or is abandoned.
With each transmission report from memory, a reduced
version of the first page is automatically reproduced.
To select the report type:
231 - SETUP / SEND / SEND REPORT
1 Select the required option WITH, WITHOUT,
ALWAYS or ON ERROR and confirm your choice
with OK.
Document feed type
You may choose the way you want to feed your
documents:
•from memory, transmission will take place only after
memory storage of the document and dialling.
It allows you to get your originals back quickly to free
up the machine.
• from the feeder of the sheet-feed scanner,
transmission will occur after dialling and paper
scanning.
It allows transmission of larger documents.
To select the way you want to feed your documents:
232 - SETUP / SEND / MEMORY SEND.
1 Select the option MEMORY or FEEDER and
validate your choice with OK.
In feeder mode, reduced images will not appear on the
transmission report.
Important
If you define a local prefix, do not
add it to the numbers stored in
the directory, it will be
automatically dialled with each
number.