SATO M8490S Printer User Manual


 
Programming Manual 2. Command Codes
SATO RISC Printers 117
Custom Protocol Command Codes
Download
Command Structure:
<ESC>LD,a,b,c,d,e,f,g,h,i
a: Replacement character for STX in ASCII or hex format
b: Replacement character for ETX in ASCII or hex format
c: Replacement character for ESC in ASCII or hex format
d: Replacement character for ENQ in ASCII or hex format
e: Replacement character for CAN in ASCII or hex format
f: Replacement character for NULL in ASCII or hex for-
mat
g: Replacement character for OFFLINE in ASCII or hex
format
h: Auto-Online. Printer powers up in the On Line mode.
0=Yes
1=No
i: Zero Slash. Places a slash through the “0” character.
0=Yes
1=No
Example: <ESC>LD,{,},%,#,&,*,~,0,0
Placement: Immediately following the <ESC>A Start command and
in an independent data stream.
Default: Standard Protocol command Codes
Function:
Allows the user to defines custom Protocol Command codes.
Input:
<ESC>A
<ESC>LD,{,},%,#,&,*,~,0,0
<ESC>Z
Output:
A Protocol Command code status label will be printed as a result of the
a successful download of a custom set of Protocol Command codes.