156 SATO RISC Printers
4. Bar Code Specifications Programming Manual
Label Set #2
Note:
1. The maximum number of <ESC>FX Sequential Numbering com-
mands that can be used in one job is eight.
2. In the example above four total labels will be printed
(<ESC>FX002+005003<ESC>DC00006000), the sequential num-
bering will start at position 5 and the three digits “600” will be
incremented in steps of 1. A total of two sets of labels will be
printed, the first set of two labels with the value “00006000” and
the next two label set with the value “00006010”.
Label Set #1 Label Set #2
1st Label 00006000 3rd Label 00006010
2nd Label 00006000 4th Label 00006010
3. The <ESC>Q Label Quantity command must be set for the total
number of labels to be printed. In the above example, the value
for the <ESC>Q command should be 2 sets x 2 labels/set = 4. If,
in the above example, it was set to a value of “1”, only the first
label would be printed.