Seagate ST3160812SV Laptop User Manual


 
16
SV35 Series SATA Product Manual, Rev. B
Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and
begins counting down from its specified delay times to zero. If the standby timer reaches zero before any
drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the
drive accepts all commands and returns to Active mode when disc access is necessary.
2.9 Environmental specifications
2.9.1 Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed 69°C (156°F) within the operating ambient conditions. Rec-
ommended measurement locations are shown in Figure 6.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 44°C (112°F) at 10,000 feet
(3,048 meters).
2.9.2 Temperature gradient
2.9.3 Humidity
2.9.3.1 Relative humidity
2.9.3.2 Wet bulb temperature
2.9.4 Altitude
Operating: 0° to 60°C (32° to 140°F)
Nonoperating: –40° to 70°C (–40° to 158°F)
Operating: 20°C per hour (68°F per hour max), without condensation
Nonoperating: 30°C per hour (86°F per hour max)
Operating: 5% to 90% noncondensing (30% per hour max)
Nonoperating: 5% to 95% noncondensing (30% per hour max)
Operating: 37.7°C (99.9°F max)
Nonoperating: 40°C (104°F max)
Operating: –60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)
Nonoperating: –60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)